ELC-40/50/60/80
- In SAFETY LOCK ELC there are two kinds setting side for right-hand and left-hand. R and L in the end of model show right-hand and left-hand for each setting. When ordering, please specify the required installation.
- Winding drum torque shows the reference value calculated based on maximum shutter load and 20mm of slat depth.
- SAFETY LOCK ELC is not applicable for any other bracket except the specified one.
- Use environment: Ambient temperature; -15℃ to +40℃ (subject to no freezing・dew condensation) Ambient humidity less than 85%RH
- Durability: 15,000 open/close (in normal shutter). This is subject to the conditions that the device must be replaced when it worked by suddenly fallen shutter.
- You can download PDF catalog down below and for details or inquiry, please contact us!
Specification
ELC-40/50/60/80
Model | ELC-40-BCR(L) ELC-40-BTR(L) |
ELC-50-BCR(L) ELC-50-BTR(L) |
ELC-60-BTR(L) | ELC-80-BTR(L) | ||||
---|---|---|---|---|---|---|---|---|
Drum sprocket | #41-T50 | #40-T60 | #41-T50 | #40-T60 | #50-T42 | #50-T52 | #60-T50 | #80-T48 |
Operating Speed of Drum Shaft (r.p.m) |
23~26 | 28~31 | 23~26 | 28~31 | 27~30 | 22~24 | 16~18 | 14~16 |
Max. Load of Shutter (Drum size)(kg) |
209(4B) | 250(4B) | 258(4B) | 310(4B) | 400(5B) | 500(5B) | 700(6B) | 900(8B) |
Winding Drum Torque (N・m) |
137 | 164 | 169 | 204 | 313 | 391 | 635 | 1042 |
Applicable Operator | ULC- 10G | ULC- 12G ULC- 12GSC |
ULC- 25G ULC- 25GSC |
ULA- 50G2 | ULA- 75G | |||
Applicable Shutter Speed (m/min) |
Less than 4.5(10.5 r.p.m) | Less than 6(8.2 r.p.m) | Less than 6(8.8 r.p.m) | |||||
Device Stop Position (mm) |
Less than 150(measured in the position of 500mm from the lower-limit.) | |||||||
Product Weight (kg) |
1.5 | 1.5 | 3.5 | 6.5 |