Products

ULC-25G

  • ULC-25G
  • ULC-25G
  1. The figures in the winding capacity and minimum fall load are obtained with the use of 5B drum. When the 4B drum is used, the winding capacity is reduced to 1.15 times from the above ratings.
  2. “a/b” in speed and full-load current are measured under the 50Hz; “a” and 60Hz; “b” power respectively.
  3. Use environment: Ambient temperature; -10℃ to +40℃ (subject to no freezing・dew condensation). Ambient humidity less than 85%RH.
  4. Time rating is the value measured at +20℃. If the temperature exceeds this value, the time rating gets shorter.
  5. Shutter shall be surely equipped with the emergency limit switch.
  6. Durability: 10,000 opening and closing
  7. It is available to produce the operator with different operating voltage except for above.
  8. You can download PDF catalog and manual down below and for details or inquiry, please contact us!

Specification

ULC-25G
Model ULC-25G
Voltage Single-phase 220V Three-phase 400V

Drum Sprocket
#50-T52
Standard

Winding Capacity(kg) 500(4903N)
Min. Fall Load(kg) 10(98N)
Winding Drum Speed(r.p.m) 3.4/4.5 4.2/5.1
Drum Sprocket
#50-T42
High-speed
Winding Capacity(kg) 400(3923N)
Min. Fall Load(kg) 8(78.5N)
Winding Drum Speed(r.p.m) 4.2/5.6 5.2/6.3
Output Shaft Torque(N・m) 88.2
Min. Fall Torque(N・m) 1.47
Speed(r.p.m) 17.5/23.6 21.9/26.3
Motor Output(kW) 0.25
Speed(r.p.m) 1080/1450 1350/1620
Full-load Current(A) 2.7/2.7 0.86/0.69
Time Rating(Minute) 5
Max. Range of Limit Switch(Turns) 650(in Output Shaft)
Sprocket(Output side/Drum side) #50-T10/#50-T52, T42
Roller Chain #50-70 Links(T52), #50-64 Links(T42)
Operator Weight(kg) 15.5 13.5

Page Top