ULA-50G
- “a/b” in s peed and full-load current are measured under the 50Hz : “a” and 60Hz ” b” power respectively.
- Use environment: Ambient temperature; -10℃ to +40℃ (subject to no freezing・dew condensation). Ambient humidity less than 85%RH.
- Time rating is the value measured at +20℃. If the temperature exceeds this value , the time rating gets shorter.
- Shutter shall be surely equipped with the emergency limit switch.
- Durability : 10.000 opening and closing
- It is available to produce the operator with different operating voltage except for above.
- You can download PDF catalog and manual down below and for details or inquiry, please contact us!
Specification
ULA-50G
Model | ULA-50G | ||
---|---|---|---|
Voltage | Single-phase 100V | Three-phase 200V | |
Winding Capacity(kg) | 650(6370N) | 700(6860N) | |
Min. Fall Load(kg) | 14(137.2N) | 12(117.6N) | |
Winding Drum Speed(r.p.m) | 3.1/3.8 | 3.5/4.1 | |
Output Shaft | Torque(N・m) | 122 | 147 |
Min. Fall Torque(N・m) | 2.0 | ||
Speed(r.p.m) | 15.7/19.2 | 17.3/20.7 | |
Motor | Output(kW) | 0.4 | |
Speed(r.p.m) | 1250/1530 | 1380/1650 | |
Full-load Current(A) | 7.1/8.7 | 3.0/2.3 | |
Time Rating(Minute) | 10 | ||
Sprocket(Output side/Drum side) | #60-T10/T50 | ||
Roller Chain | #60-63 Links(Bracket Type: BA-50M) #60-65 Links(Bracket Type: BA-50L) |
||
Operator Weight(kg) | 30 | 22 |